FC-202P11KT4E55H2XGXXXXSXXXXAXBXCXXXXDX
VLT®AQUA Drive FC 200
11 KW / 15 HP, 380 - 480 VAC,
IP55 / Type 12, RFI Class A2 (C3),
No brake chopper.
CHARACTERISTIC |
VALUE |
PRODUCT GROUP |
(FC-) VLT® AQUA Drive FC- |
SERIES |
202 |
POWER RATING |
(P11K) 11 KW / 15 HP |
PHASE |
(T) Three phase |
MAINS VOLTAGE |
(4) 380 - 480 VAC |
ENCLOSURE |
(E55) IP55 / Type 12 |
RFI FILTER |
(H2) RFI Class A2 (C3) |
BRAKE - SAFE STOP |
(X) No brake chopper |
LCP |
(G) Graphical Loc. Cont. Panel |
COATING PCB |
(X) Not coated PCB |
MAINS OPTION |
(X) No Mains Option |
ADAPTATION A |
(X) Standard Cable Entries |
ADAPTATION B |
(X) No adaptation |
SOFTWARE RELEASE |
(SXXX) Latest release std. SW. |
SOFTWARE LANGUAGE PACK |
(X) Standard Language Pack |
A OPTION |
(AX) No A Option |
B OPTION |
(BX) No B Option |
C0 OPTION MCO |
(CX) No C0 option |
C1 OPTION |
(X) No C1 option |
C OPTION SOFTWARE |
(XX) No software option |
D OPTION |
(DX) No D option |
FRAME SIZE |
B1 |
TYPECODE PART 1 |
FC-202P11KT4E55H2XGX |
TYPECODE PART 2 |
XXXSXXXXAXBXCXXXXDX |
PRODUCT CATALOG |
Global (Standard) |
VENDOR |
Factory DK |
MATERIAL GROSS WEIGHT |
21.292 |
MATERIAL NET WEIGHT |
20.992 |
Danfoss FC202
Mã sản phẩm: Biến Tần Danfoss FC202
Thương hiệu: Danfoss
Xuất Xứ : Đan Mạch
Giá : Liên hệ Mr Phương - 094 5050 500
Hoặc gửi email: kythuatviettien@gmail.com
Biến tần Danfoss VLT® AQUA Drive FC202 Chuyên dụng trong cấp nước và xử lý nước thải, điều khiển bơm điều áp và chạy luân phiên các bơm trong hệ thống / Khi mua thêm bộ rơ le mở rộng thì bộ sơ le này được tích hợp sẵn PLC cơ bản và lúc này biến tần chạy tăng cường đến 8 bơm mà không dùng đến PLC lắp thêm bên ngoài,cấp bảo vệ đến IP68, màn hình hiển thị 5 thông số đồ họa,công suất lên đến 1400Kw. Thiết kế nhỏ gọn nhằm hạ giá thành đến mức thấp nhất,nhưng tích hợp đầy đủ các dạng kết nối truyền thông và SCADA. Xuất xứ: Denmark - Hàng NK Châu Âu Chất lượng cao
Qúy khách mua biến tần về tự lắp đặt theo hướng dẫn của Catalogue hoặc liên hệ Công ty Việt Tiến để được tư vấn kỹ du cầu cần sự dụng,Hoặc có thể mua trọn bộ gồm tủ điện và biến tần lắp vào tủ- Khách hàng đưa ra nguyên lý và chức năng cần của tủ-Công ty Việt Tiến sẽ thiết kế miễn phí đúng với du cầu-Khách hàng có thể tham khảo các tủ ở danh mục tủ điện công ty Việt Tiến đã làm.
Các mã hàng thông dụng, có sẵn:
FC-202PK75T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8886
FC-202P1K1T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8894
FC-202P1K5T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8649
FC-202P2K2T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8903
FC-202P3K0T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8912
FC-202P4K0T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8920
FC-202P5K5T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8940
FC-202P7K5T4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131B8650
FC-202P11KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6637
FC-202P15KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6641
FC-202P18KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6645
FC-202P22KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6765
FC-202P30KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6770
FC-202P37KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6775
FC-202P45KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6650
FC-202P55KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6654
FC-202P75KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6658
FC-202P90KT4E20H2XGXXXXSXXXXAXBXCXXXXDX Code no: 131F6663
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, the VLT® AQUA Drive provides the lowest overall cost of ownership for water and wastewater applications.
Power and voltage range
200-240 V ..... 0.25 kW - 45 kW
380-480 V ..... 0.37 kW - 1000kW
525-600 V ..... 0.75 kW - 90 kW
525-690 V ..... 45 kW - 1,4 MW
Three phase
3*200-240V… 0,25-45kW
3*380-480V… 0,37-1000kW
3*525-600V… 0,75-90kW
3*525-690V… 11-1200kW
Single phase
1*200-240V 1,1-22kW
1*380-480V 7,5-37kW
Enclosures
IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X
Dedicated water features Auto tuning of the PI controllers
With auto tuning of the PI controllers, the drive monitors how the system reacts on corrections made by the drive - and learns from it, so that precise and stable operation is achie ved quickly.
Pipe Fill Mode
Enables controlled (closed loop) filling of pipes. Prevents water hammering, bursting water pipes or blowing off sprinkler heads.
End of Pump Curve detects breaks and leakage
The feature detects breaks and leakage. End of curve triggers an alarm, shuts off the pump, or performs another userdefined action.
Dry Pump Protection lowers maintenance costs
The VLT® AQUA Drive constantly evaluates the condition of the pump, based on internal frequency/power measurements.
Standard cascade controller
The in-built cascade controller controls up to three pumps with fixed lead pump.
Motor Alternation
This built-in logic controls alternation between two pumps in duty/stand-by applications. Motion of the stand-by pump prevents sticking of the pump. An internal timer assures equal usage of the pumps.
Flow compensation
The flow compensation feature reduces the pressure set point according to the flow - which saves energy.
Initial/Final Ramp
The initial ramp provides fast acceleration of pumps to minimum speed, from where the normal ramp takes over. This prevents damage on thrust and bearings. Sensorless Pressure or Flow Control
Safety
The VLT® AQUA Drive can optionally be delivered with the safe stop functionality suitable for category 3 installations according to EN 954-1. This feature prevents the drive from starting unintended.
A wide selection of accessories is available for the VLT® AQUA Drive to suit your needs. For further details see the Operation Instructions.
Options
Options for bus communication, user programs, etc., are delivered ready for plug and play.
Display options
Local Control Panel LCP (graphical and numerical)Cable for LCP, 3 m [9,8 ft.] Remote-mounting kit for Local Control Panel (LCP)
Application options
External 24 V supply card
Serial Communication OptionsProfibus Option Card (MCA-101)DeviceNet Option Card (MCA-104)Ethernet IP (MCA-121)
I/O options
General Purpose I/O (MCB 101),
Relay Option (MCB 105),
Extended cascade option (MCO-101),
Advanced cascade option (MCO-102),
Analogue input option (MCB109),
External 24VDC supply option (MCB-107)
Sensor input option(MCB114)
Filters
Harmonic Filter (AHF 005/010 MCE) Sine-Wave Filters (MCC 101) dU/dt filter (MCC 102)
Other accessories
IP21/NEMA1 Kit
USB connection cable to PC
Harmonic Filter cable to PC
FC-202P11KT4E55H2XGXXXXSXXXXAXBXCXXXXDX
VLT®AQUA Drive FC 200
11 KW / 15 HP, 380 - 480 VAC,
IP55 / Type 12, RFI Class A2 (C3),
No brake chopper.
CHARACTERISTIC
VALUE
PRODUCT GROUP
(FC-) VLT® AQUA Drive FC-
SERIES
202
POWER RATING
(P11K) 11 KW / 15 HP
PHASE
(T) Three phase
MAINS VOLTAGE
(4) 380 - 480 VAC
ENCLOSURE
(E55) IP55 / Type 12
RFI FILTER
(H2) RFI Class A2 (C3)
BRAKE - SAFE STOP
(X) No brake chopper
LCP
(G) Graphical Loc. Cont. Panel
COATING PCB
(X) Not coated PCB
MAINS OPTION
(X) No Mains Option
ADAPTATION A
(X) Standard Cable Entries
ADAPTATION B
(X) No adaptation
SOFTWARE RELEASE
(SXXX) Latest release std. SW.
SOFTWARE LANGUAGE PACK
(X) Standard Language Pack
A OPTION
(AX) No A Option
B OPTION
(BX) No B Option
C0 OPTION MCO
(CX) No C0 option
C1 OPTION
(X) No C1 option
C OPTION SOFTWARE
(XX) No software option
D OPTION
(DX) No D option
FRAME SIZE
B1
TYPECODE PART 1
FC-202P11KT4E55H2XGX
TYPECODE PART 2
XXXSXXXXAXBXCXXXXDX
PRODUCT CATALOG
Global (Standard)
VENDOR
Factory DK
MATERIAL GROSS WEIGHT
21.292
MATERIAL NET WEIGHT
20.992